Installation and Operating Guide DS9000 Series

Seite 2 - Copyright Notice

x Safety Notices Precautions Do not use oil, solvents, gasoline, paint thinners or insecticides on the unit. Do not expose the unit to moisture, to t

Seite 3 - Copyright Notice (Europe)

xi Table of Contents Copyright Notice...

Seite 4

xii Table of Contents Why the Use Cleaning Tape LED Gets Turned ON...

Seite 5 - Regulatory Notices

1 Chapter 1 Introduction This Chapter. . . provides a physical description of the switches, indicators and connectors on the front and rear panels o

Seite 6 - CE Notice

2 Equipment Description The ADIC DS9000 Series consists of several models: the ADIC 4000, DS9400D/L, DS9700D and DS9800D. All are SCSI compatible, h

Seite 7

Introduction 3 Caution SE and LVD/SE SCSI devices are not compatible with HVD SCSI devices. Equipment damage may occur if you connect your DS9000 S

Seite 8 - DECLARATION OF CONFORMITY

4 Figure 2. DS9700D Front Panel

Seite 9 - Safety Notices

Introduction 5 Figure 3. DS9400D/L Front Panel (ADIC 4000 does not include the LCD)

Seite 10 - Precautions

6 Front Panel Indicators and Controls 2-line by 20-character LCD Display Displays drive status, error messages, POST results Beeper Sounds whenever

Seite 11 - Table of Contents

Introduction 7 Rear Panel Controls and Connectors Figure 4 shows the controls and connectors located on the rear panel of the DS9000 Series. SCSI C

Seite 12

ii Copyright Notice Copyright ADIC 1995, 1996, 1997, 1998, 1999, 2000, 2001 The information contained in this document is subject to change without

Seite 13 - Chapter

8 Rear Panel Controls and Connectors Control or Connector Purpose Power Switch Turns power to the unit on and off. AC Power Connector Receptacle fo

Seite 14 - Equipment Description

Introduction 9 Figure 5. DLT Data Cartridge Cautions Always remove any cartridge from the drive before turning off host system power. Failure to r

Seite 15 - Caution

10 Blank Page

Seite 16

11 Chapter 2 Installation This Chapter. . . explains the steps necessary to install and test the DS9000 Series Devices. provides a symbol next to

Seite 17 - Introduction

12 Installation Unpacking and Inspecting Caution If the operating environment differs from the storage environment by 15° C (30° F) or more, let the

Seite 18

Installation 13 Note Make sure that the SCSI cable between the host adapter and the DS9000 Series is secure and the connections are fastened correc

Seite 19

14 Installation Setting the SCSI ID The SCSI address of the DS9000 Series may need to be changed, depending upon factors in the setup, operating syst

Seite 20 - Data Cartridge

Installation 15 The SCSI ID switch is located on the rear of the DS9000 Series (see Figure 7). Use a small pointed object to press either the + but

Seite 21 - Other Requirements

16 Installation Note Installing the Application Software Refer to the application software installation guide and install the backup software, if nec

Seite 22 - Blank Page

17 Chapter 3 Operation and Maintenance This Chapter . . . describes normal operating features of the DS9000 Series.explains how, and when to clean t

Seite 23

iii Copyright Notice (Europe) © Copyright ADIC Europe 1995, 1996, 1997, 1998, 1999, 2000, 2001 All rights reserved. No part of this document may

Seite 24 - Unpacking and Inspecting

18 Operation and Maintenance Power-on Self-Test When the system power is ON, the DLT drive performs a Power-on Self-Test (POST). The sequence of eve

Seite 25 - 4DS9X00Units

Operation and Maintenance 19 LCD Messages (DS9400D/L, DS9700D and DS9800D) The following table describes the messages displayed on the LCD during a

Seite 26 - Setting the SCSI ID

20 Operation and Maintenance LED Indicators Use the following table to determine the drive’s operating condition: Right Indicator Panel LED Label Co

Seite 27

Operation and Maintenance 21 Left Indicator Panel LED Label Color State Operating Condition 2.6 (ADIC 4000, DS9400D/L, DS9700D) Yellow ON Blinking

Seite 28 - Installation

22 Operation and Maintenance LCD Messages (DS9400D/L, DS9700D and DS9800D only) The following table describes the messages displayed by the LCD duri

Seite 29

Operation and Maintenance 23 Drive Operating Condition LCD Message When tape is loaded. “type” = 4000 OMX (DS9400D/L), 7000 OMX (DS9700D) or 800

Seite 30 - Power-on Self-Test

24 Operation and Maintenance Drive Operating Condition LCD Message Whenever the system is writing to a tape, these two messages will alternate. Each

Seite 31

Operation and Maintenance 25 Drive Operating Condition LCD Message If new tape, or the drive cannot initialize the tape. followed by: followed

Seite 32 - LED Indicators

26 Operation and Maintenance Figure 8. Loading a Data Cartridge Insert the data cartridge into the slot. Push the cartridge into the drive. Push t

Seite 33 - Operation and Maintenance

Operation and Maintenance 27 Data Protection Write-Protection of the Data Cartridge While Inside the Drive The Write-Protect switch on the data car

Seite 34

iv Blank Page

Seite 35

28 Operation and Maintenance Removing the Data Cartridge Caution Remove a cartridge from the drive before turning OFF host system power. Failure to

Seite 36 - Drive Operating Condition

Operation and Maintenance 29 If the DS9000 Series device fails to operate correctly, immediately call the ADIC Customer Assistance Center (refer to

Seite 37 - Loading the Data Cartridge

30 Operation and Maintenance Note Loading the cleaning cartridge into the drive at the end of its cleaning cycle will result in a failed or shortene

Seite 38

31 Chapter 4 Troubleshooting and Diagnostics This Chapter. . . Lists a number of common problems and the actions to take to correct them. provides i

Seite 39 - Tape in Use

32 Troubleshooting and Diagnostics Troubleshooting Chart If the DS9000 Series fails during POST or operation, use the following table to determine t

Seite 40 - Cleaning the Tape Head

Troubleshooting and Diagnostics 33 If . . . Then . . . Response . . . The SCSI terminator may not be at the end of the bus, or more than two te

Seite 41

34 Troubleshooting and Diagnostics Use Cleaning Tape LED If an excessive number of read-after-write errors are detected during normal operation of t

Seite 42 - Cleaning the Enclosure

Troubleshooting and Diagnostics 35 Defective drive. Drive amplifier settings could be off, causing error rate degradation. The drive may have faile

Seite 43 - This Chapter. .

36 Troubleshooting and Diagnostics When Assistance is Required Calling ADIC’s Technical Assistance Center (ATAC) Customer Support is provided free o

Seite 44 - Troubleshooting Chart

37 Appendix A Specifications This Appendix . . . contains specification information on the DS9000 Series.

Seite 45

v Regulatory Notices FCC Notices (USA Only) This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used i

Seite 46 - Example

38 Specifications Drive Type: Quantum DLT4000 Quantum DLT7000 Quantum DLT8000 ADIC 4000, DS9400D/L DS9700D DS9800D Data Transfer Rate (compressed mo

Seite 47 - High Humidity

39 Appendix B Drive Configuration This Appendix . . . describes the options that can be selected by installing jumpers on the DLT Tape Drives.

Seite 48 - When Assistance is Required

40 Drive Configuration SCSI Bus Parity DLT4000 Drives If the host computer system does not generate SCSI bus parity, disable the parity checking func

Seite 49 - Appendix

Drive Configuration 41 DLT7000/DLT8000 Drives If the host computer system does not generate SCSI bus parity, disable the parity checking procedure i

Seite 50 - 180 MB/min

42 Drive Configuration SCSI Bus Termination and Terminator Power Note The SCSI bus must be terminated at both ends, and at least one device must supp

Seite 51

Drive Configuration 43 1No Term PowerDisable Active Termination2No Term PowerEnable A ctive Term ination3Term PowerDisable Active Termination4Term P

Seite 52 - SCSI Bus Parity

44 Drive Configuration FrontBezelRight SideTRM PWR ConnectorDFDT Connector Figure 15. DLT7000/DLT8000 Tape Drive Connectors (right side) TERMPOWER F

Seite 54 - Warning

46 Index # 10.0 format, 21 10.0 GB format, 6 10.0 GB tape format, 2 15.0 format, 21 15.0 GB format, 6 2.6 format, 21 2.6 GB format, 6 2.6 GB tape for

Seite 55 - DLT7000/DLT8000 Drives

Index 47 host adapter, 9, 13 host computer, 8, 9, 12, 16, 40, 41 humidity, 34 Humidity, 35, 38 I I/O connector, 9 installing backup software, 16 in

Seite 56

vi IC Notice (Canada Only) Most tape libraries are classified by the Industry Canada (IC) Interference-Causing Equipment Standard #3 (ICES-003) as C

Seite 57

48 Index V ventilation, 35 Vibration, 38 W warranty, ii, iii, 12, 29, 36 weight, 38 write enabled, 6 Write Protected LED, 6, 18, 20, 27 write-enabled

Seite 58

vii EN 61000-4-6 — “Immunity to conducted disturbances, induced by radio-frequency fields.” — Severity level 2. EN 61000-4-8 — “Power frequency m

Seite 59

viii DECLARATION OF CONFORMITY according to EN 45014 Manufacturer’s Name: Advanced Digital Information Corporation Manufacturer’s Address: 11

Seite 60

ixSafety Notices Warnings This symbol should alert theuser to the presence of"dangerous voltage" insidethe product that might causeharm

Kommentare zu diesen Handbüchern

Keine Kommentare