Seitenansicht 32
Operation and Maintenance 23
Tape in Use
Whenever the Tape in Use LED (yellow) is ON steady, the tape is ready to use. When the tape is being
read, written, or rewound, Tape in Use blinks.
Use the following table to determine what is happening during cartridge use:
Right Indicator Panel
LED State Meaning
Tape in Use
ON steady
Blinks irregularly
Blinks regularly
A cartridge is loaded, but the tape is not moving. This
can mean no application is communicating with the
controller, or that the application is communicating
but is not delivering commands for tape motion.
A read or write is in progress.
Tape is loading, unloading, or rewinding.
Operate
Handle
ON and beeper sounds Tape is unloaded into the cartridge and the cartridge
can now be removed, or if the drive is unloaded, a
cartridge can now be inserted.
All LEDs Blinking An error has occurred during operation.
Removing a Data Cartridge
Caution
Remove a cartridge from the drive before turning OFF host system power.
Failure to remove a cartridge before turning OFF host system power can result
in cartridge and drive damage.
To unload a cartridge from the drive perform the following steps:
1. Push the Unload button.
4 The Tape in Use LED will blink as the tape rewinds.
Caution
A data cartridge can only be unloaded when the Operate Handle LED is ON.
Do not attempt to open the Cartridge Insert/Release Handle unless this
LED is ON steady.
2. When the Operate Handle LED is ON (and the beeper has sounded), pull the Cartridge
Insert/Release Handle open to eject the cartridge from the drive.