Managing the AMASS File System
4-76 Utility Reference 6-00028-01 Rev A
Field Description
Dead Blocks Amount of previously written space on the volume that
is no longer referenced by files
This is expressed as a percentage of the total volume
space; the higher the percentage, the greater the
amount of dead space.
NOTE: Volumes with high percentages are good
candidates for the volcomp process.
Errors Number of errors on this volume
Volume Label The user-assigned volume label or preprinted barcode
Field Description
The following two fields are valid if you use the -a
option.
Block Size Tape’s block size
Compression Data compression. Valid values are:
On (default) = compression ON
Off = compression OFF
Dflt = compression is undetermined because
media is un-formatted