Managing the AMASS File System
6-00028-01 Rev A Operational Tasks 2-37
MAXIOSZ Changes
If you want to change the MAXIOSZ, perform the following
steps:
Step Command
1 Log in as amass or root.
2 Remove your current Backup Volume (containing a backup
of the AMASS File System Database and transaction file)
from the library, label it with the “old”
MAXIOSZ value, and
store the volume in a safe place.
3 Upgrade to the current version of AMASS.
4 Immediately create a new Backup Volume with the
amassbackup command.
5 Label the new Backup Volume with the “new”
MAXIOSZ
value.
6 To recover data on the old Backup Volume, return the
MAXIOSZ parameter on AMASS to the old setting before
attempting to read the old Backup Volume